This option causes the Cary system to use the deuterium lamp to calibrate the
instrument at 2624.4, 1312.2 and 0.00 nm.
Note
When performing a wavelength calibration you must firstly remove the DRA,
perform the calibration, then return the DRA to the instrument. Refer to the
Wavelength Accuracy
help in the Validate application.
Calibration using Cary Win UV Software
The recommended method for performing calibration is by using the Auto Calibrate
function in the Validate application.
Caution
Both instrument and DRA are calibrated at the factory and should be recalibrated only
when tests indicate the need for it. Failure to complete or the use of incorrect filters
may render the instrument unusable.
Signal processing
This causes the Cary system to calibrate the programmable gain amplifiers on the
photomultiplier tube. This test is performed during initialization of the Cary
4000/5000/6000i instruments.
UV/Vis 0 %T correction
This causes the Cary system to close the shutter and calibrate the UV/Vis detector for
0 %T errors. If a DRA is connected a mask must be placed in front of the transmission
port (rear instrument beam) during the calibration process. The software will prompt
you for this.
Note
This calibration is part of the normal initialization procedure, however
calibration is advised when working at high absorbance where a repeat
calibration after the instrument is fully warmed up would be beneficial.
NIR 0%T correction
This closes the shutter and calibrates the NIR detector for 0 %T errors. If a DRA is
connected a mask must be placed in front of the transmission port (rear instrument
beam) during the calibration process. The software will prompt you for this.
Auto calibrate
Will perform all the calibrations relevant to the instrument and DRA combination
being used. User interaction is required if a DRA is in place.